phone Phone
+6281519124415
close
menu

CV. Dwi Jaya Suplindo

sql
SMOKE DETECTOR NOTIFIER FSP 851 ORI
SMOKE DETECTOR NOTIFIER FSP 851 ORI
SMOKE DETECTOR NOTIFIER FSP 851 ORI
Hover to Zoom

Jual SMOKE DETECTOR NOTIFIER FSP 851 ORI



Spesifikasi SMOKE DETECTOR NOTIFIER FSP 851 ORI

ALAT PEMADAM KEBAKARAN LAINNYA

Spesifikasi Photoelectric Smoke Detector Addressable FSP-851 Notifier

detektor asap General

Notifier FSP-851(A) Series intelligent plug-in smoke detectors

with integral communication provide features that surpass

conventional detectors. Detector sensitivity can be

programmed in the control panel software. Sensitivity is continuously

monitored and reported to the panel. Point ID capability

allows each detector’s address to be set with rotary,

decimal address switches, providing exact detector location

for selective maintenance when chamber contamination

reaches an unacceptable level. The FSP-851(A) photoelectric

detector’s unique optical sensing chamber is engineered

to sense smoke produced by a wide range of combustion

sources. Dual electronic thermistors add 135°F (57°C) fixedtemperature

thermal sensing on the FSP-851T(A). The FSP-

851R(A) is a remote test capable detector for use with

DNR(A)/DNRW duct detector housings. FSP-851(A) series

detectors are compatible with Notifier Onyx and CLIP series

Fire Alarm Control Panels (FACPs).

FlashScan® (U.S. Patent 5,539,389) is a communication

protocol developed by Notifier that greatly increases the

speed of communication between analog intelligent devices.

Intelligent devices communicate in a grouped fashion. If one

of the devices in the group has new information, the panel’s

CPU stops the group poll and concentrates on single points.

The net effect is response speed greater than five times that

of earlier designs.

Features

• Sleek, low-profile design.

• Addressable-analog communication.

• Stable communication technique with noise immunity.

• Low standby current.

• Two-wire SLC connection.

• Compatible with FlashScan® and CLIP protocol systems.

• Rotary, decimal addressing (1-99 on CLIP systems, 1-159

on FlashScan systems).

• Optional remote, single-gang LED accessory.

• Dual LED design provides 360° viewing angle.

• Visible bi-color LEDs blink green every time the detector is

addressed, and illuminate steady red on alarm (FlashScan

systems only).

• Remote test feature from the panel.

• Walk test with address display (an address on 121 will

blink the detector LED: 12-[pause]-1(FlashScan systems

only).

• Built-in functional test switch activated by external magnet.

• Built-in tamper-resistant feature.

• Sealed against back pressure.

• Constructed of off-white fire-resistant plastic, designed to

commercial standards, and offers an attractive appearance.

• 94-5V plastic flammability rating.

• SEMS screws for wiring of the separate base.

• Optional relay, isolator, and sounder bases.

Specifications

Sensitivity: 0.5% to 2.35% per foot obscuration

Size: 2.1" (5.3 cm) high; base determines diameter.

– B210LP(A): 6.1" (15.5 cm) diameter.

– B501(A): 4.1" (10.4 cm) diameter.

– B200S(A): 6.875" (17.46 cm) diameter.

– B200SR(A): 6.875" (17.46 cm) diameter.

– B224RB(A): 6.2" (15.748 cm) diameter.

– B224BI(A): 6.2" (15.748 cm) diameter.

Shipping Weight: 5.2oz. (147g).

Operating Temperature range: FSP-851(A), 0°C to 49°C

(32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F).

Low temperature signal for FSP-851T(A) at 45°F +/- 10°F

(7.22°C +/- 5.54°C). FSP-851R(A) installed in a DNR(A)/

DNRW, -20°C to 70°C (-4°F to 158°F).

UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/

min.), suitable for installation in ducts.

Relative Humidity: 10%-93% noncondensing.

Thermal Ratings: Fixed-temperature setpoint 135°F (57°C).

DETECTOR SPACING AND APPLICATIONS

Notifier recommends spacing detectors in compliance with

NFPA 72. In low airflow applications with smooth ceiling,

space detectors 30 feet (9.144m) for ceiling heights 10 feet

(3.148m) and higher. For specific information regarding

detector spacing, placement, and special applications refer to

NFPA 72. System Smoke Detector Application Guide, document

A05-1003, is available at systemsensor.com